P Ower S Upplies And T Wo C Omputers - Ametek Sorensen XG Operation Manual

Programmable dc power supply 670 watts – 1700 watts
Table of Contents

Advertisement

Local Computer #1
Figure 6-30 Multiple Power Supplies and Two Computers
All devices connect via the HUB. Every device must have a unique IP
address, for example:
You must set up every device manually.
To set up for multiple power supplies and two computers:
1.
2.
3.
4.
5.
M370430-01 Rev B
HUB
ENET
Power Supply #1
Power Supply #2
Computer #1: 169.254.117.231
Computer #2: 169.254.117.232
Power supply #1: 169.254.117.220
Power supply #2: 169.254.117.221
Power supply #3: 169.254.117.222
Power supply #30: 169.254.117.230.
Set up your computer as described in "Setting Up the
Computer" on page 6-5. Repeat the procedure for each
computer hooked up to the system.
Install the DeviceInstaller software on the PC you wish to use
to configure the XG/XTR unit (s) with. See the instructions
for "Software Installations" on page 6-8.
Configure each XG/XTR unit with an ENET option. See the
instructions for "Configuring the Device Using
DeviceInstaller" on page 6-10.
Create terminal connections for each of the XG/XTR unit (s)
with the ENET option that were configured in step 3. See the
instructions for "Terminal Configuration" on page 6-16.
If more than one computer is going to be used, copy the
filename.ht files saved in step 3 to a disk and copy them over
Communications Options
Local Computer #2
Power Supply #30
ENET
ENET
6
6-25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sorensen xtrSorensen xg seriesSorensen xtr series