Table 5-11 Oper Ations; R Egister - Ametek Sorensen XG Operation Manual

Programmable dc power supply 670 watts – 1700 watts
Table of Contents

Advertisement

Remote Operation
Table 5-11 OPERation Status Register
Bit
Bit Weight Bit Name
0
1
CALibrating
1
2
SETTling
2
4
RANGing
3
8
SWEeping
4
16
MEASuring
5
32
Waiting for Arm
6
64
Waiting for Trigger
7
128
CORRecting
8
256
Not Used
9
512
SHUTdown Summary
10
1024
Local Lockout
11
2048
Current Share Summary Reflects the summary of the CSHare Sub-Register.
12
4096
Constant Voltage Mode
13
8192
Constant Current Mode
14
16384
Program Running
5-40
Description
Indicates that the supply is in CALibration Mode.
Not implemented
Not implemented
Not implemented
Not implemented
Not implemented
Not implemented
Not implemented
Not Used
Reflects the summary of the SHUTdown
Sub-Register.
Front panel lockout
Reflects the output mode of the supply.
Reflects the output mode of the supply.
Indicates if an Autosequence program is currently
running.
The operation shutdown status register describes the cause of the
power supply shutting down the output. More than one bit may be
active and multiple actions will be required to restart the unit. The
protection shutdown sub-register indicates which protection
mechanisms have caused the power supply to shutdown.