Operation Status Register Commands - Ametek Sorensen XG Operation Manual

Programmable dc power supply 670 watts – 1700 watts
Table of Contents

Advertisement

Operation Status Register Commands

The response format for all register queries will be in decimal notation.
Query Operation Status Register Event
SCPI command:
[:]STATus[<channel>]:OPERation[:EVENt]?
Query Operation Status Register Condition
SCPI command:
[:]STATus[<channel>]:OPERation:CONDition?
Enable Operation Status Register
SCPI command:
[:]STATus[<channel>]:OPERation:ENABle
Query Format:
[:]STATus[<channel>]:OPERation:ENABle?
Set Operation Status Positive Transition Filter
SCPI command:
[:]STATus[<channel>]:OPERation:PTRansition
<status-enable>
Query Format:
[:]STATus[<channel>]:OPERation:PTRansition?
Set Operation Status Negative Transition Filter
SCPI command:
[:]STATus[<channel>]:OPERation:NTRansition
<status-enable>
Query Format:
[:]STATus[<channel>]:OPERation:NTRansition?
M370430-01 Rev B
Remote Operation
<status-enable>
5-43
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sorensen xtrSorensen xg seriesSorensen xtr series

Table of Contents