Command Error List; R Egisters - Ametek Sorensen XG Operation Manual

Programmable dc power supply 670 watts – 1700 watts
Table of Contents

Advertisement

Command Error List

Table B-1
Error
Code
-100
-102
-108
-109
-110
-113
-121
-140
-150
-151
M370430-01 Rev B
An error in the range [-199, -100] indicates that an IEEE 488.2
syntax error has been detected by the instrument's parser. The
occurrence of any error in this class causes the command error bit
(bit 5) in the Event Status Register to be set.
Command Error List
Error Message Description
Command error This is the generic syntax error
Syntax Error An unrecognized command or data type was
encountered; for example, a string was received when the device
does not accept strings.
Parameter not Allowed More parameters were received than
expected for the header; for example, the *SRE common
command only accepts one parameter, so receiving *SRE 0,1 is
not allowed.
Missing Parameter Fewer parameters were received than
required for the header; for example, the *SAV common
command requires one parameter, so receiving *SAV is not
allowed.
Command header error An error was detected in the header.
Undefined header The header is syntactically correct, but it is
undefined for this specific device; for example, *XYZ is not
defined for any device.
Invalid character in number An invalid character for the data
type being parsed was encountered; for example, an alpha in a
decimal numeric or a "9" in octal data.
Character data error This error is generated when parsing a
character data element.
String data error This error is generated when parsing a string
data element fails.
Invalid string data A string data element was expected, but was
invalid for some reason (see IEEE 488.2, 7.7.5.2); for example,
an END message was received before the terminal quote
character.
Error Messages
B
B-3