Remote Operation

Protection Mask (Enable Alarms)

The protection mask allows for the different alarms to be masked,
completely disabling them. This means that the SCPI status and
operations registers will not detect the alarms. You will have no way of
knowing the current operation state of the alarm. The protection mask is
a feature that is only accessible using the SCPI command noted below.
Command:
[:]SYSTem[<channel>]:PROTection[:MASK] {?|<mask>}
Table 5-19 Alarms Bit Mask
Bit
0
1
2
3
4
5
6
7
8
9
10
5-74
Where
<mask> is the bit mask for disabling the alarms. See Table 5-19 for
details.
Bit Weight Bit Name
1
AC Fail
2
OTP
4
Fan Slave
8
Fan Stop
16
OTP Slave
32
Interlock
64
OVP
128
OCP
256
Foldback
512
Shutdown
1024
UVP
See "Alarms and Errors" on page 3-21.
Description
Not used. Always 1.
Not used. Always 1.
Fan on the slave board (1500W
and 1700W models only)
Fan on the main board.
Over Temperature protection
on the slave board (1500W and
1700W models only).
Not used. Always 1.
Not used. Always 1.
Not used. Always 1.
Foldback protection.
External Shutdown pin
Under Voltage protection.