Shipped Configuration (Local Operation)

The power supply is configured for local operation at the factory. See
Table 3-3 for a summary of this configuration. For more information on
default settings, see Table 3-9 on page 3-43.
Table 3-3
Local Control Configuration
Use the front panel controls to
adjust the output voltage and
current set point settings.
The OVP set point is adjusted at
the front panel to 105% above
the maximum rated output
voltage.

Enabling the Output

Enabling the output on will also turn off the ALARM LED if the
ALARM LED has been latched on due to an alarm triggering and
automatically clearing. See "Alarms and Errors" on page 3-21.
To enable the output power:
To disable the output power:
Important: The main output will not turn on if the shutdown function is
activated. See "Using the External Shutdown Function" on page 3-33.
Quick Tip Remote
The SCPI command (s) for these instructions are:
Operation uses these
[:]OUTPut[<channel>][:POWer][:STATe]
commands. See page
5-1.
M370430-01 Rev B
Shipped Configuration
Press the OUTPUT ENABLE Main button on the front panel or
enter the SCPI command.
The OUTPUT ENABLE Main button will illuminate.
Press the OUTPUT ENABLE Main button when the OUTPUT
ENABLE Main button is illuminated.
The output will be disabled and the LEDs will not be illuminated.
Additional References
See Chapter 3, "Local Operation" for front
panel operation. See Chapter 4, "Analog
Programming (APG) and Isolated Analog
Programming (ISOL)" for analog
programming procedures.
See "Using Over Voltage Protection (OVP)"
on page 3-28 for the adjustment procedure.