Scpi Command Summary - Ametek Sorensen XG Operation Manual

Programmable dc power supply 670 watts – 1700 watts
Table of Contents

Advertisement

SCPI Command Summary

The SCPI commands supported by this programmable power supply are described in the tables in the
remainder of this section. These tables use the following column headings:
Function The commonly used name for the function.
SCPI Command The full command in long form.
Description Explains what the command does or what is affected by it.
Query? Indicates whether the unit supports a query version of the listed command. N/A indicates Not
applicable. (The command has no query form and will respond with an error if queried.)
Table A-1
IEEE 488.2 Commands
Function
SCPI Command
Select Address *ADR
*CLS [:]STATus[<channel>]:CLEar
Clear Status
*ERR
Query the Error
Queue
*ESE?
Standard Event
[:]STATus[<channel>]:STANdard:ENABle
Status Enable
Query
*ESE
Standard Event
[:]STATus[<channel>]:STANdard:ENABle
Status Enable
<ESE-word>
*ESR?
Standard Event
[:]STATus[<channel>]:STANDard[:EVENt]?
Status Register
Query
Parameter and
Description
Range
Select the power supply unit
?|<Address (1–30)> Yes
to communicate with.
Clears all the status data
structures.
Query the Error Queue for the
oldest error event.
Query the Standard Event
Status Enable register
settings.
Set the Standard Event Status
<Enable Flags(0–
Enable Register bits.
255)>
Query the Standard Event
Status Register (SERS).
Query
N/A
Yes
N/A
Yes

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sorensen xtrSorensen xg seriesSorensen xtr series

Table of Contents