Questionable Status Register Commands - Ametek Sorensen XG Operation Manual

Programmable dc power supply 670 watts – 1700 watts
Table of Contents

Advertisement

Questionable Status Register Commands

Query Questionable Status Register Event
SCPI command:
[:]STATus[<channel>]:QUEStionable[:EVENt]?
Query Questionable Status Register Condition
SCPI command:
[:]STATus[<channel>]:QUEStionable:CONDition?
Enable Questionable Status Register
SCPI command:
[:]STATus[<channel>]:QUEStionable:ENABle
<status-enable>
Query Format:
[:]STATus[<channel>]:QUEStionable:ENABle?
Set Questionable Status Positive Transition Filter
SCPI command:
[:]STATus[<channel>]:QUEStionable:PTRansition
<status-enable>
Query Format:
[:]STATus[<channel>]:QUEStionable:PTRansition?
Set Questionable Status Negative Transition Filter
SCPI command:
[:]STATus[<channel>]:QUEStionable:NTRansition
<status-enable>
Query Format:
[:]STATus[<channel>]:QUEStionable:NTRansition?