Error Messages - Ametek CSW5550 User Manual

Csw series ac power source
Table of Contents

Advertisement

User Manual

9. Error Messages

Any errors that occur during operation from either the front panel or the remote control interface
will result in error messages. Error messages are displayed in the upper left hand corner of the
LCD display. They are also stored in the error message queue from which they can be queried
using the SYST:ERR? Query. The error queue has a finite depth. If more error messages are
generated than can be held in the queue, a queue overflow message will be put in the last
queue location. To empty the queue, use the error query until the No Error result is received.
Errors appearing on the LCD will generally remain visible until the user moves to another screen.
If multiple error messages are generated in succession, only the last message will be visible as
there is only space for one error message on the LCD display.
The same area of the display is also used to display status messages. While error messages
always have a negative error number, status messages have a positive number.
The table below displays a list of possible error and status messages along with their possible
cause and remedy.
Number
Message String
0
"No error"
-100
"Command error"
-102
"Syntax error"
-103
"Invalid separator"
-104
"Data type error"
"Parameter not
-108
allowed"
-109
"Missing parameter"
-110
"Command header
error"
-111
"header separator
error"
-112
"Program mnemonic
too long"
-113
"Undefined header"
-120
"Numeric data error"
-121
"Invalid character in
number"
-123
"Exponent too large"
-128
"Numeric data not
allowed"
CSW Series
Cause
Remedy
No errors in queue
Unable to complete
Unit may be in a mode inconsistent
requested operation
with request.
Command syntax
Misspelled or unsupported command
incorrect.
SCPI separator not
See SCPI section of programming
recognized
manual.
Data type invaled.
Check command for supported data
types
One or more
Check programming manual for
additional parameters
correct number of parameters
were received.
Too few parameters
Check programming manual for
received for
correct number of parameters
requested operation
Command header
Check syntax of command.
incorrect
Invalid command
Use semi-colon to separate command
separator used.
headers
Syntax error
Check programming manual for
correct command syntax
Command not
Check programming manual for
recognized error
correct command syntax
Data received is not a
Check programming manual for
number
correct command syntax
Number received
Check programming manual for
contains non-numeric
correct command syntax
character(s)
Exponent in number
Check programming manual for
exceeds limits
correct parameter range
Number received
Check programming manual for
when number is not
correct command syntax
allowed.