Table 10-2: Bit Configuration Of Standard Event Status Enable Register - Ametek 2003RP User And Programming Manual

Ac power source
Table of Contents

Advertisement

10.10.1
*CLS
This command clears the following registers (see chapter 12 for descriptions of all status
registers):
Standard Event Status
Status Byte
Error Queue
Command Syntax
Parameters
10.10.2
*ESE
This command programs the Standard Event Status Enable register bits. The programming
determines which events of the Standard Event Status Event register (see *ESR?) are
allowed to set the ESB (Event Summary Bit) of the Status Byte register. A "1" in the bit
position enables the corresponding event. All of the enabled events of the Standard Event
Status Enable Register are logically OR-ed to cause the Event Summary Bit (ESB) of the
Status Byte Register to be set. See Section 16 for descriptions of the Standard Event Status
registers.
The query reads the Standard Event Status Enable register.

Table 10-2: Bit Configuration of Standard Event Status Enable Register

Bit Position
Bit Name
Bit Weight
CME
Command error
EXE
Execution error
PON
Power-on
Command Syntax
Parameters
Power-On Value
Example
Query Syntax
Returned Parameters
Related Commands
*CLS
None
7
6
5
PON
not used
CME
128
32
*ESE <NRf>
0 - 255
128
*ESE 129
*ESE?
<NR1>(Register value)
*ESR? *STB?
4
3
2
EXE
DDE
QYE
16
8
4
DDE
Device-dependent error
QYE
Query error
1
0
not used
not used

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents