Powering On At System Console; Figure 1-14 Slot Or Unit Number - Silicon Graphics Origin 3900 User Manual

Table of Contents

Advertisement

Powering On at System Console

007-4653-001
To power on your server at the system console, follow these steps:
1.
At your console, switch to L2 mode by pressing Ctrl+T.
2. From the L2 prompt (L2>), power on an individual brick by entering the following
command. (If you want to power on the entire server, proceed to step 3.)
<rack#>
<slot#>
L2> r
s
For example, to power on a Cx-brick in rack 1, slot 07, enter the following:
L2> r 1 s 7 pwr u
The slot number is the lowest unit number that the brick occupies within a rack. For
example, in Figure 1-14, the lowest Cx-brick is identified as U07. The next lowest
Cx-brick is identified as U11, and so on.
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
IX-brick
24
23
22
21
Cx-brick
20
19
18
17
Cx-brick
16
15
14
13
Cx-brick
12
11
10
9
Cx-brick
8
7
6
Power bay
5
4
3
Power bay
2
1
Figure 1-14
Slot or Unit Number
pwr u
Powering Server On and Off
21

Advertisement

Table of Contents
loading