The SGI UV 3000 command line interface is accessible by logging into the RMC as root.
Information on booting Linux from the shell prompt is included at the end of the subsection
("Monitoring Power On Example" on page 16). The following command options may be used
with the RMC CLI:
usage: power [-vcow] on|up [TARGET]...turns power on
-v, --verbose
verbose output
-c, --clear
clear EFI variables (system and partition targets only)
-o, --override
override partition check
-w, --watch
watch boot progress
usage: power [-vo] off |down [TARGET]...shuts power down
usage: power [-vchow] reset [TARGET]...resets the system power
usage: power [-vl0ud] status [TARGET]...checks power-on status
To monitor the power-on sequence during boot, see the next section "Monitoring Power On
Example".
Establish another connection to the RMC and use the uvcon command to open a system console
and monitor the system boot process. Use the following steps:
RMC:> uvcon
uvcon: attempting connection to localhost...
007-6402-001