Sign In
Upload
Manuals
Brands
Silicon Graphics Manuals
Server
ICE X
Silicon Graphics ICE X Server Hardware Manuals
Manuals and User Guides for Silicon Graphics ICE X Server Hardware. We have
1
Silicon Graphics ICE X Server Hardware manual available for free PDF download: User Manual
Silicon Graphics ICE X User Manual (142 pages)
Brand:
Silicon Graphics
| Category:
Server
| Size: 7 MB
Table of Contents
Record of Revision
3
Table of Contents
5
List of Figures
11
About this Guide
15
Audience
15
Important Information
15
Chapter Descriptions
16
Related Publications
17
Obtaining SGI Publications
18
Conventions
19
Product Support
19
User Input
19
Reader Comments
20
1 Operation Procedures
21
Precautions
21
ESD Precaution
21
Safety Precautions
22
Console Connections
23
Figure 1-1 Flat Panel Rackmount Console Option
23
Powering the System on and off
24
Figure 1-2 Administrative Controller Video Console Connection Points
24
Figure 1-3 Blade Enclosure Power Supply Cable Example
25
Preparing to Power on
25
Figure 1-4 Eight-Outlet Single-Phase PDU Example
26
Figure 1-5 Three-Phase PDU Examples
27
Powering on and off
28
Console Management Power (Cpower) Commands
28
Table 1-1 Cpower Option, Action, Target Type and Target List Descriptions
28
Table 1-2 Cpower Example Command Strings
31
Monitoring Your Server
32
Optional SGI Remote Services (SGI RS)
33
Figure 1-6 Blade Enclosure Chassis Management Board Locations
33
SGI Remote Service Operations Overview
34
SGI Remote Services Benefits
34
SGI Remote Services Primary Capabilities
34
Figure 1-7 SGI Remote Services Process Overview
35
2 System Management
37
Figure 2-1 SGI ICE X System Network Access Example
38
Chassis Controller Interaction
39
Chassis Manager Interconnects
40
Figure 2-2 Redundant Chassis Manager Interconnect Diagram Example
40
Figure 2-3 Non-Redundant Chassis Manager Interconnection Diagram Example
41
M-Rack Chassis Manager Interconnection
41
Chassis Management Control (CMC) Functions
42
Figure 2-4 M-Rack System Chassis Manager Interconnect Example
42
CMC Connector Ports and Indicators
43
System Power Status
43
Levels of System and Chassis Control
39
Using the 1U Console Option
39
3 System Overview
45
System Models
46
Figure 3-1 SGI ICE X Series System (Single Rack - Air Cooled Example)
46
Figure 3-2 D-Rack Blade Enclosure and Rack Components Example
48
SGI ICE X System and Blade Architectures
49
IP113 Blade Architecture Overview
49
IP115 Blade Architecture Overview
50
IP119 Blade Architecture Overview
51
IP131 Blade Architecture Overview
52
IP133 Blade Architecture Overview
53
Quickpath Interconnect Features
54
IP113, IP115 and IP119 QPI Bandwidth
54
IP131 and IP133 QPI Bandwidth
54
Blade DIMM Bandwidth Factors
55
Blade DIMM Memory Features
55
Blade Memory Features
55
Memory Channel Recommendation
55
Enclosure Switch Density Choices
56
System Infiniband Switch Blades
56
Figure 3-3 Infiniband 48-Port (Premium) FDR Switch Numbering in Blade Enclosures
57
System Features and Major Components
58
Modularity and Scalability
58
Figure 3-4 SGI ICE X System and Network Components Overview
59
System Administration Server
59
Multiple Chassis Manager Connections
60
Rack Leader Controller
60
Figure 3-5 D-Rack Administration and RLC Cabling to Cmcs Example
61
The RLC as Fabric Manager
61
Service Nodes
62
Figure 3-6 Example Rear View of a 1U Service Node
62
Login Server Function
62
Batch Server Node
63
Figure 3-7 2U Service Node Front and Rear Panel Example
63
I/O Gateway Node
63
Optional Lustre Nodes Overview
64
MDS Node
64
OSS Node
65
Reliability, Availability, and Serviceability (RAS)
65
System Components
67
Figure 3-8 SGI ICE X Series D-Rack Blade Enclosure Pair Components Example
68
Figure 3-9 Single-Node D-Rack Blade Enclosure Pair Component Front Diagram
69
Figure 3-10 M-Rack Blade Enclosure Pair Components Example
70
D-Rack Unit Numbering
71
Optional System Components
71
Rack Numbering
71
Optional SGI Remote Services (SGI RS)
71
SGI Remote Services Primary Capabilities
72
SGI Remote Services Benefits
72
SGI Remote Service Operations Overview
73
Figure 3-11 SGI Remote Services Process Overview
73
SGI Warranty Levels
74
4 Rack Information
75
Overview
75
SGI ICE X Series D-Rack (42U)
76
Figure 4-1 SGI ICE X Series D-Rack Example
77
Figure 4-2 Front Lock on Tall (42U) D-Rack
78
Figure 4-3 Optional Water-Chilled Door Panels on Rear of ICE X D-Rack
79
Figure 4-4 Air-Cooled D-Rack Rear Door and Lock Example
80
ICE X D-Rack Technical Specifications
81
Table 4-1 Tall SGI ICE X D-Rack Technical Specifications
81
SGI ICE X M-Cell Rack Assemblies
82
Figure 4-5 M-Cell Rack Configuration Example (Top View)
82
M-Cell Functional Overview
83
Table 4-2 SGI ICE X M-Rack Technical Specifications
83
Figure 4-6 SGI ICE X Multi-Cell (M-Cell) Rack Array Example
84
Figure 4-7 Half M-Cell Rack Assembly (½-Cell) Example
85
5 SGI ICE X Administration/Leader Servers
87
Overview
88
System Hierarchy
88
Communication Hierarchy
89
Figure 5-1 SGI ICE X System Administration Hierarchy Example Diagram
90
1U Rack Leader Controller and Administration Server
91
Figure 5-2 1U Rack Leader Controller (RLC) Server Front and Rear Panels
91
1U Service Nodes
92
C1104G-RP5 1U Service Node
92
Figure 5-3 SGI Rackable C1104G-RP5 1U Service Node Front and Rear Panels
93
Figure 5-4 SGI Rackable C1104G-RP5 System Control Panel and Leds
93
2U Service Nodes
94
Figure 5-5 8-HDD Configuration RP2 Service Node Front Panel Example
94
Figure 5-6 C2108-RP2 Service Node Front Control Panel-Horizontal Layout
94
RP2 2U Service Nodes
94
RP2 Service Node Front Controls
94
Table 5-1 C2108-RP2 Control Panel Components
95
Figure 5-7 RP2 Service Node Back Panel Components Example
96
RP2 Service Node Back Panel Components
96
Table 5-2 RP2 Service Node Back Panel Components
96
C2110G-RP5-P 2U Service Node
97
Figure 5-8 Front and Rear Views of the SGI C2110G-RP5-P 2U Service Node
97
Table 5-3 C2110G-RP5-P 2U Server Control Panel Functions (Listed Top to Bottom)
98
Figure 5-10 SGI UV 20 Service Node Front Panel Example
99
Figure 5-11 SGI UV 20 Service Node Rear Panel and Component Descriptions
99
SGI UV 20 2U Service Node
99
Figure 5-12 SGI UV 20 Service Node Front Control Panel Description
100
6 Basic Troubleshooting
101
Troubleshooting Chart
102
Table 6-1 Troubleshooting Chart
102
LED Status Indicators
103
Blade Enclosure Pair Power Supply Leds
103
Figure 6-1 Power Supply Status LED Indicator Locations
103
Table 6-2 Power Supply LED States
103
IP113 Compute Blade Leds
104
Figure 6-2 IP113 Compute Blade Status LED Locations Example
104
IP115 Compute Blade Status Leds
105
Figure 6-3 IP115 Compute Blade Status Leds Example
105
IP119 Compute Blade Status Leds
107
Figure 6-4 IP119 Blade Status Leds Example
107
IP131 Compute Blade Status Leds
108
Figure 6-5 IP131 Compute Blade Status LED Locations Example
108
IP133 Compute Blade Status Leds
109
Figure 6-6 IP133 Blade Status Leds Example
109
Accessing Online Support Information and Services
110
SGI Customer Portal
110
Other Resources
111
SGI Warranty Levels
111
Technical Assistance
111
Optional SGI Remote Services (SGI RS)
112
7 Maintenance Procedures
113
Maintenance Precautions and Procedures
113
Preparing the System for Maintenance or Upgrade
114
Installing or Removing Internal Parts
114
Table 7-1 Customer-Replaceable Components and Maintenance Procedures
114
Replacing ICE X System Components
115
Removing and Replacing a Blade Enclosure Power Supply
115
Figure 7-1 Removing an Enclosure Power Supply
116
Figure 7-2 Replacing an Enclosure Power Supply
117
Removing and Replacing Rear Fans (Blowers)
118
Figure 7-3 Enclosure-Pair Rear Fan Assembly (Blowers)
119
Figure 7-4 Removing a Fan from the Rear Assembly
120
Figure 7-5 Replacing an Enclosure Fan
121
Removing or Replacing a Fan Enclosure Power Supply
122
Removing a Fan Assembly Power Supply
122
Replacing a Fan Power Supply
122
Figure 7-6 Removing a Power Supply from the Fan Power Box
123
Figure 7-7 Replacing a Power Supply in the Fan Power Box
124
Overview of PCI Express Operation
125
Figure 7-8 Comparison of PCI/PCI-X Connector with PCI Express Connectors
125
Table 7-2 SGI Administrative Server Pcie Support Levels
126
Technical Specifications and Pinouts
127
System-Level Specifications
127
Table A-1 SGI ICE X Series Configuration Ranges
127
D-Rack Physical and Power Specifications
128
Table A-2 ICE X System D-Rack Physical Specifications
128
D-Rack System Environmental Specifications
129
Table A-3 Environmental Specifications (Single D-Rack)
129
ICE X M-Rack Technical Specifications
130
Table A-4 SGI ICE X M-Rack Physical Specifications
130
Table A-5 Environmental Specifications (Single M-Rack)
131
Ethernet Port Specification
132
Figure A-1 Ethernet Port
132
Table A-6 Ethernet Pinouts
132
Safety Information and Regulatory Specifications
133
Safety Information
133
Regulatory Specifications
135
CMN Number
135
CE Notice and Manufacturer's Declaration of Conformity
135
Electromagnetic Emissions
135
FCC Notice (USA Only)
136
Industry Canada Notice (Canada Only)
136
Chinese Class a Regulatory Notice
137
Figure B-1 VCCI Notice (Japan Only)
137
Figure B-2 Chinese Class a Regulatory Notice
137
Figure B-3 Korean Class a Regulatory Notice
137
Korean Class a Regulatory Notice
137
VCCI Notice (Japan Only)
137
Electrostatic Discharge and Laser Compliance
138
Shielded Cables
138
Lithium Battery Statements
139
Index
141
Advertisement
Advertisement
Related Products
Silicon Graphics ISS3500
Silicon Graphics Altix ICE 8000 Series
Silicon Graphics ICE XA
Silicon Graphics InfiniteStorage 350
SGI InfiniteStorage IS350
SGI InfiniteStorage IS220
SGI InfiniteStorage IS4100
SGI InfiniteStorage IS-DMODULE
SGI InfiniteStorage IS5012
SGI InfiniteStorage IS5024
Silicon Graphics Categories
Server
Desktop
Storage
Monitor
Computer Hardware
More Silicon Graphics Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL