1: Operation Procedures
22
If you want to power on several selected bricks from a rack at the same time, you
must enter the rack number followed by the slot numbers of the bricks you want to
power on. For example, to power on bricks in slots 7 and 11 of rack 4, enter the
following command:
L2> r 4 s 7,11 pwr u
If you want to power on the bricks that reside in the same slot in multiple racks, you
must enter the number of the racks followed by the slot number of the bricks you
want to power on. For example, to power on the bricks in slot 11 of racks 3 and 4,
enter the following command:
L2> r 3, 4 s 11 pwr u
Note: To avoid problems with your server, do not try to power on multiple slots for
multiple racks at the same time.
3. If you want to power on the entire server, enter the following command:
L2> pwr u
(The default setting for the pwr u command is all racks and all slots.)
4. From the L2 prompt, display the system configuration by entering the following
command:
L2> config
This command lists the bricks in the server and each brick's system controller
address.