007-4653-001
Table 11-3 provides temperature and humidity requirements for the D-brick2.
Table 11-3
D-brick2 Ambient Temperature and Humidity Requirements
Factor
Operating temperature
Non-operating temperature
Storage temperature
Shipping temperature
Table 11-4 provides additional environmental specifications for the D-brick2.
Table 11-4
D-brick2 Environmental Requirements
Environmental Factor
Altitude, operating
Altitude, non-operating
Shock, operating
Shock, non-operating
Vibration, operating
Vibration, non-operating
Acoustics
Safety and approvals
EMC
Technical and Environmental Specifications
Temperature
Relative Humidity
5 °C to 40 °C
20% to 80% noncondensing
(41 °F to 104 °F)
0 °C to 50 °C
8% to 80% noncondensing
(32 °F to 122 °F)
1 °C to 60 °C
8% to 80% noncondensing
(34 °F to 140 °F)
-40 °C to +60 °C
5% to 100% nonprecipitating
(-40 °F to 140 °F)
Requirement
0 to 3047 m (0 to 10,000 ft)
-305 to 12,192 m (-1000 to 40,000 ft)
Vertical axis 5 g peak 1/2 sine, 10 ms
30 g 10 ms 1/2 sine
0.21 grms 5-500 Hz random
1.04 grms 2-200 Hz random
Less than 6.0 B LwA operating at 20 °C
CE, UL, cUL
EN55022 (CISPR22-A), EN55024 (CISPR24), FCC-A
Maximum
Wet Bulb
23 °C
(73 °F)
27 °C
(80 °F)
29 °C
(84 °F)
29 °C
(84 °F)