103-336 ESS RAM DIMM #3 W/r Check Failure

A failure was detected during Read/Write Check of the ESS RAM DIMM #3.
Procedure
Switch the power off then on. The fault is cleared.
Y
N
Remove and replace the ESS RAM DIMM #3.
If the problem continues, replace the ESS ROM DIMM #3
Return to Service Call Procedures.
Initial issue
DC 3535/2240/1632, WC M24
103-337 ESS Standard RAM Error
An error was detected in the ESS built-in standard RAM.
Procedure
Switch the power off then on. The fault is cleared.
Y
N
Replace the ESS PWB
(PL
13.1).
Return to Service Call Procedures.