Calibrating Label Sensors
If the label sensors are not locating the beginning and ends of your labels
properly, they can be calibrated with the Calibrate Sensor command.
Note: The sensors may not work if they need cleaning. Follow the procedures in
Chapter 10 before calibrating.
To calibrate your label sensors
1. Start at the OFFLINE READY display.
2. Press [MENU]. Proceed to press [ ] or [ ] until you see:
3. Press [SELECT]. The display shows:
4. Press [ ] or [ ] until you see:
5. Press [SELECT]. The display shows:
9-16
DATA LINE PRINT
DISABLED*
asterisk next to the new selection. The display shows:
DATA LINE PRINT
ENABLED*
The printer will now print characters received from the host.
The data line print automatically returns to DISABLED after you exit this
menu. Press [ONLINE/OFFLINE] to return to normal printing.
OFFLINE READY
SERVICE MENU
SERVICE MENU
PRINT PAGE
SERVICE MENU
CALIBRATE SENSOR
CALIBRATE SENSOR
GAP