4400 Bar Code Label Printer User's Manual

Audible Alarm, Enable or Disable

Turns the audible alarm feature on or off.
Purpose:
n = 0
Default:
Syntax:
<SI>a n
n = 0
n = 1
Notes:
This command is effective upon execution.

Auto-Transmit 1, Enable

Purpose:
Enables auto-transmit level 1.
Syntax:
<ESC>j
The status response codes are as follows:
<DC1>
<FS>
<BS>
<EM>
<US>
<US>
Notes:
The printer automatically transmits the status response codes listed above
when necessary.
This command becomes effective upon execution.

Auto-Transmit 2, Enable

Purpose:
Enables auto-transmit level 2.
Syntax:
<ESC>d
Notes:
At level 2, the printer automatically transmits the status response code <DC1>
(room in input buffer).
This command becomes effective upon execution.
7-34
Disables the audible alarm.
Enables the audible alarm.
Fault cleared
Label at strip pin
Takeup reel full
No label stock
Ribbon fault
Label path open