Human-Readable Field, Create Or Edit; Human-Readable Text, Define Border Around - Intermec 4400 User Manual

Bar code label printer
Hide thumbs Also See for 4400:
Table of Contents

Advertisement

Height Magnification, Define (continued)
Syntax:
hn
n values can range between 1 and 250 for human-readable fields and graphics.
For bar code and box fields, the range for n is from 1 to 9999.
Notes:
For human-readable fields, graphics, and the POSTNET symbology, n
represents the vertical magnification of the character bitmap.

Human-Readable Field, Create or Edit

Purpose:
Use this command to edit or create a human-readable field n.
n = 0
Default:
Syntax:
H n [, name ]
n values can range between 0 and 199.
,name is an optional field. The field can be up to eight ASCII characters except
for semicolon, but cannot start with a numeric character.
Notes:
If n does not exist, a default human-readable field is created.
Parameters for the default field:
Field origin
Field direction
Character rotation
Font
Height magnification
Width magnification
Pitch
Point
Border
Data origin
Data length

Human-Readable Text, Define Border Around

Purpose:
Defines a border around a human-readable field.
Default:
n = 0
Syntax:
b n
n values range from 0 to 199.
NugFont
HelvC
0,0
0 degrees
0 degrees
7x9 standard
2
2
disabled
disabled
disabled
Print mode
30
No borders (black letters).
C o d e 3 9