Printer Functional Boundaries

Every printer feature has a functional limit that assumes unlimited common
memory. Since several functions may compete for common memory, the
memory limit may be reached before the functional limit is reached.
For example, even though you have a functional limit of 20 formats, you may
run out of memory before you can store 20 formats if you have downloaded
several large graphics. In cases like this, you may want to restructure your data
or purchase additional printer memory.
Parameter
Bar Code Height
Bar Code Narrow Bar Multiplier
Characters in a Field (Including Control
Characters and Delimiters)
Characters in a Field Name
Field Data Offset
Fields in a Format
Font Character Size
Formats
Formats in a Page
Graphic Size
Graphics
Image Bands
Increment or Decrement Skip Value
Languages
Length or Width of a Line or Box
Pages
Quantity or Batch Size
Slaves to a Field
User-Defined Fonts
7-80
Functional Limit
50 inches
50
200
8
9999
200
3 sq. inches
20 including default
26
4 sq. inches
100
10
9999
8 per seven-bit character set; 1 per
eight-bit character set
9999 dots (50 inches)
10 including default
9999
20
16