Intermec 4400 User Manual page 135

Bar code label printer
Hide thumbs Also See for 4400:
Table of Contents

Advertisement

NugFont
HelvC
The <STX> and <ETX> characters mark the beginning and end of each
command string. The semicolon (;) is the command terminator. All commands
in Program mode must end with this terminator except the last command in a
message. The other characters are described in the table below.
Command
Description
<ESC>C
Sets 4400 (advanced) mode.
<ESC>P
Enters Program mode.
E3;
Erases anything previously stored as format three.
F3;
Creates format three.
H0;
Designates field zero as a human-readable field.
o162,200;
Sets the origin at grid coordinates (162,200).
f0;
Sets the field rotation to zero, which is unrotated or horizontal.
c2;
Selects internal font two.
d0,16;
Determines that data is sent during print mode and its maximum length is 16
characters.
h2;
Sets the height magnification factor to twice its original height.
w2;
Sets the field width magnification factor to twice its original width.
H1;
Defines field one as a human-readable field.
o162,300;
Sets the field origin at coordinates (162,300).
f0;
Sets the rotation factor of the field to zero.
c2;
Selects internal font two.
d3,Warehouse
Determines that data for the field has this constant value: Warehouse Part # 3666.
Part # 3666;
h2;
Sets the field height magnification factor to twice its original height.
w2;
Sets the field width magnification factor to twice its original width.
B2;
Defines field two as a bar code field.
o162,400;
Sets the origin at coordinates (162,400).
f0;
Sets the field rotation to zero (unrotated).
c0,1;
Selects Code 39 with a check digit entered by the printer.
h100;
Sets the field height to 100 dots.
C o d e 3 9
Designing Labels and Using Commands