GBC F - 160 Operation And Maintenance Manual page 18

Gbc laminator user manual
Table of Contents

Advertisement

F - 160 Operation and Maintenance Manual
An important feature of the F-160 laminator are
the safety shields, when raised, the auto run is disabled
and drive control is transferred to the footswitch.
Figure 1.2.2 illustrates the safety shields in the up
position.
Caution should always be exercised
when using the laminator with
the safety shields raised.
You can be seriously HURT or INJURED!
Figure 1.2.2 Safety shields raised
Rear safety
shield
The laminator is equipped with two
EMERGENCY STOPS located on the top of either
side of the laminator. To engage the EMERGENCY
STOP feature, press down on either one. Either of
these, when engaged, stops the laminator. Refer to
Figure 1.2.3 for illustration.
© GBC Pro - Tech August 1999
WARNING
Front safety
shield
Figure 1.2.3 Emergency stops
Plane4
Plane4
To continue operation, both EMERGENCY
STOPS ( E-STOPS ) must be in the up position. To
reset the E-STOP, twist the button 1/4 turn clockwise.
Refer to Figure 1.2.4 for illustration.
Figure 1.2.4 Reset E-Stop buttons
Safety
Plane4
Unlatch
Page 1 - 3