Clock Set - D-Link DGS-6600-48TS Manual

Modular layer 3 chassis ethernet managed switch
Hide thumbs Also See for DGS-6600-48TS:
Table of Contents

Advertisement

DGS-6604
m

clock set

clock set HH:MM:SS DAY MONTH YEAR
Syntax Description
HH:MM:SS
DAY
MONTH
YEAR
Default
Command Mode
Usage Guideline
Example
Switch# clock set 18:00:00 22 Aug 2010
Switch#
CLI Reference Guide
Use this command to manually set the system clock.
Current time in hours (24-hour format), minutes and seconds.
Current day (by date) in the month.
Current month (by name, January, Jan, February, Feb, and so on).
Current year (no abbreviation).
Hardware Generated - 00:00:00 01 January 1993
Privileged EXEC at Privilege level 15
Generally, if the system is synchronized by a valid outside timing mechanism,
such as SNTP, it is not necessary to set the clock manually. Use this command if
no other time sources are available. Use the clock timezone command on
page 120 to configure the time zone applied to the clock settings. The clock
configured by this command will be applied to RTC if it is available. The
configured clock will not be stored in the configuration file.
If the clock is manually set and the SNTP server is configured, the system will still
try to sync the clock with the server. If time sync is successful, the SNTP server
set time replaces the manually set time.
If the SNTP state changes from enabled to disabled, the system clock continues
operations but no longer attempts to sync time with the server.
The following example shows how to manually set the software clock to 6:00
p.m. on Aug 22, 2010:
Verify the settings by entering the show clock command.