Error Message
sw intialization return_code [hex] ([chars]).
XBAR_CLIENT Messages
This section contains the XBAR_CLIENT messages.
XBAR_CLIENT-2
Error Message
Error Message
Error Message
Error Message
[chars].
XBAR_CLIENT-3
Error Message
code = [dec]
Cisco NX-OS System Messages Reference
2-828
XBAR-5-XBAR_SW_INIT_FAIL: Xbar [[dec].[dec]] reported failure durinig
Explanation
The supervisor has experienced an crossbar setup failure.
No action is required.
Recommended Action
XBAR_CLIENT-2-MEM_FULL: memory allocation failed
Explanation
Process xbar_client failed to allocate memory.
Please examine the xbar-client event-history for more information.
Recommended Action
XBAR_CLIENT-2-PROC_DN: exiting: [chars].
Process xbar_client is exiting.
Explanation
Please examine the xbar-client event-history for more information.
Recommended Action
XBAR_CLIENT-2-PROC_INITFAIL: initialization failed due to [chars]
Process xbar_client failed initialization.
Explanation
Please examine the xbar-client event-history for more information.
Recommended Action
XBAR_CLIENT-2-PROC_INITFAIL: Process initialization failed due to
XBAR_CLIENT process has failed initialization.
Explanation
Recommended Action
Enter a 'show xbar-client event-history' to collect more information.
XBAR_CLIENT-3-IPC_MSGERR: failure processing IPC message [dec], error
Process xbar_client failed to process IPC message.
Explanation
Recommended Action
Please examine the xbar-client event-history for more information.