SVC_BATTERY-SLOT# Messages
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
Error Message
with battery [dec].
Error Message
permitted range for battery conditioning (5C-40C).
Error Message
battery [dec] ([hex]).
SVC_BATTERY-SLOT#-4
Error Message
the required threshold.
SVC_BATTERY-SLOT#-6
Error Message
the required threshold.
Error Message
permitted range for battery conditioning (5C-40C). Battery [dec] conditioning
cancelled.
Cisco NX-OS System Messages Reference
2-670
SVC_BATTERY-SLOT#-2-COMMUNICATION_FAILURE: Communication failure
Explanation
The module encountered failures while communicating with a battery.
Replace the battery.
Recommended Action
SVC_BATTERY-SLOT#-2-CONDITIONING_DISABLED: Temperature outside
The temperature of the line card is not within the range to permit battery conditioning.
Explanation
Make sure the temperature of the line card is between 5C and 40C.
Recommended Action
SVC_BATTERY-SLOT#-2-DISCHARGING_FAILURE: Discharging failure in
The module encountered failures while discharging a battery.
Explanation
Replace the battery.
Recommended Action
SVC_BATTERY-SLOT#-4-BATTERY_CAPACITY_LOW: Battery capacity is below
The battery is lower than the required threshold.
Explanation
Make sure the temperature is within the range to allow charging.
Recommended Action
SVC_BATTERY-SLOT#-6-BATTERY_CAPACITY_OK: Battery capacity is above
The battery is above the required threshold.
Explanation
Recommended Action
No action is required.
SVC_BATTERY-SLOT#-6-CONDITIONING_CANCELLED: Temperature outside
Explanation
The temperature of the line card is not within the range to permit battery conditioning.
Make sure the temperature of the line card is between 5C and 40C.
Recommended Action
Chapter 2
System Messages and Recovery Procedures
OL-15994-03
Need help?
Do you have a question about the AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?
Questions and answers