SVC Messages
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
Error Message
SS_EID_VL_ER_MDISK_RESOURCE_RAN_OUT ) Too many Managed Disks were presented to the
cluster [chars]
Explanation
node.
Recommended Action
cluster discovery operation to find devices. 3. List all connected managed disks. Check that the
configuration is as expected. Mark the error you have just repaired as fixed.
Error Message
SS_EID_VL_ER_QUORUM_DISK_CREATION_FAILURE ) A suitable Managed Disk for use as a
Quorum Disk was not found [chars]
Explanation
automatically selected as quorum disks. A quorum disk is needed to enable a tie-break when some
cluster members are missing. To become a quorum disk: The Mdisk must be accessible by all nodes
in the cluster and the Mdisk must have free extents. This error code is produced when at least one
quorum disk is not accessible by all nodes in the cluster. A quorum disk might not be available
because of a fibre-channel network failure or because of a fibre-channel switch zoning problem.
Recommended Action
Mdisks have been created and that those mdisks have free extents. 3. List the manage disks. If at
least one managed disk shows a mode of managed, mark the error you have just repaired as fixed.
4. If the customer is unable to make the appropriate changes, contact the Cisco Technical Assistance
Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message
SS_EID_VL_ER_QUORUM_DISK_NOT_AVAILABLE ) Quorum Disk not available [chars]
Explanation
Recommended Action
disk status. If any managed disks are offline or excluded perform the disk controller problem
determination and repair procedures for the managed disks. 3. Start a cluster discovery operation. 4.
Check managed disk status. If all managed disks show a status of online, mark the error you have
just repaired as fixed.
Error Message
) Attempt to delete SSH keys (no effect) [chars]
Explanation
Volume Controller for Cisco MDS 9000, but is retained for compatibility.
Recommended Action
Support web site http://www.cisco.com/tac.
Cisco NX-OS System Messages Reference
2-638
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
The configuration is not valid. Too many devices have been presented to the cluster or
1. Remove unwanted devices from the fibre-channel network fabric. 2. Start a
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
No Mdisk is suitable for use as a quorum disk. When a cluster is created three disks are
1. Resolve any known fibre-channel network problems. 2. Confirm that
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
One or more quorum disks were not discovered by the node.
1. Resolve any known fibre-channel network problems. 2. Check managed
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_ERR_CFG_ALL_SSH_KEYS_REMOVED
'svctask rmallsshkeys' command has been invoked. This command has no effect in SAN
Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Chapter 2
System Messages and Recovery Procedures
OL-15994-03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents

Save PDF