SVC_BATTERY-SLOT# Messages
This section contains the SVC_BATTERY-SLOT# messages.
SVC_BATTERY-SLOT#-2
Error Message
temperature [dec] C is outside the operational range (-10C to 65C).
Error Message
present.
Error Message
range for battery charging (5C-40C).
Error Message
[dec] ([hex]).
Error Message
battery conditioning will be affected.
OL-15994-03
SVC_BATTERY-SLOT#-2-BATTERY_NOT_OPERATIONAL: Battery [dec]
Explanation
The battery temperature is outside the operational range (-10C to 65C).
Verify fan operation with [show environment fan], and take action to cool
Recommended Action
down the switch.
SVC_BATTERY-SLOT#-2-BATTERY_NOT_PRESENT: Battery [dec] is not
Explanation
The line card does not have sufficient number of batteries. Two batteries are needed.
Remove the line card and plug in batteries in the battery slots that are empty.
Recommended Action
SVC_BATTERY-SLOT#-2-CHARGING_DISABLED: Temperature outside permitted
The temperature of the line card is not within the range to permit battery charging.
Explanation
Make sure the temperature of the line card is between 5C and 40C.
Recommended Action
SVC_BATTERY-SLOT#-2-CHARGING_FAILURE: Charging failure in battery
The module encountered failures while charging a battery.
Explanation
Recommended Action
Replace the battery.
SVC_BATTERY-SLOT#-2-CLOCK_INCORRECT: System clock is running behind,
Explanation
The Vegas system clock is running behind the actual time. This will affect the battery
conditioning.
Recommended Action
Use clock set command to set the correct time.
SVC_BATTERY-SLOT# Messages
Cisco NX-OS System Messages Reference
2-669