Chapter 2
System Messages and Recovery Procedures
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
Error Message
Logical Fibre Channel port reported failed [chars]
Explanation
Recommended Action
Error Message
Logical Fibre Channel port missing [chars]
Explanation
Recommended Action
Error Message
Logical Fibre Channel port reported not operational [chars]
Explanation
Recommended Action
Error Message
Node warmstarted due to software error [chars]
Explanation
cluster.
Recommended Action
configuration dump and a logged data dump. Save the dump data. 3. Contact the Cisco Technical
Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac. 4. Mark the
error you have just repaired as fixed.
Error Message
Power domain error [chars]
Explanation
Recommended Action
a node to the IO group which is not on the same Caching Services Module.
Error Message
SS_EID_VG_ER_MDISK_GROUP_OFFLINE ) A Managed Disk group is offline [chars]
Explanation
Recommended Action
operation. 3. Check managed disk status. If all managed disks show a status of online, mark the error
you have just repaired as fixed.
OL-15994-03
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_FC_ADAP_FAIL )
No active/functioning logical FC port was detected by the software.
Reload the node. If the problem persists, replace the Caching Services Module.
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_FC_ADAP_QUANTITY )
No active/functioning FC port was detected by the software.
Reload the node. If the problem persists, replace the Caching Services Module.
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_FC_PORT_QUANTITY )
No active/functioning logical FC port was detected by the software.
Reload the node. If the problem persists, replace the Caching Services Module.
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_NODE_WARMSTART )
The error that is logged in the cluster error log indicates a software problem in the
1. Ensure that the software is at the latest level on the cluster. 2. Run a
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_POWER_DOMAIN )
The two nodes in an IO group are on the same Caching Services Module.
Determine what the configuration should be. Remove one of the nodes and add
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
An Mdisk group is offline.
1. Repair the enclosure or disk controller. 2. Start a cluster discovery