Flogi-1 - Cisco AP775A - Nexus Converged Network Switch 5010 Reference

Nx-os system messages reference
Hide thumbs Also See for AP775A - Nexus Converged Network Switch 5010:
Table of Contents

Advertisement

FLOGI Messages
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
Error Message
FLOGI rejected - FCID allocation failed.
Error Message
[chars]] FLOGI rejected - this interface has reached the max num of NL-Ports
([dec])
Error Message
[chars]] NPIV not supported - on this platform, NPIV is not supported on trunking
interfaces
FLOGI-2
Error Message
Interface [chars]] FLOGI rejected - ACLTCAM resource exausted
FLOGI-4
Error Message
[chars]] FLOGI with VF bit set from OUI [hex]:[hex]:[hex] (nwwn: [chars])
Cisco NX-OS System Messages Reference
2-222
FLOGI-1-MSG_FLOGI_REJECT_FCID_ERROR: [VSAN [dec], Interface [chars]]
Explanation
An FLOGI was rejected because the FCID allocation failed.
Check the fcid-interop configuration, purge the persistency table and check the
Recommended Action
output of show flogi database details and see if any of the A area FCID allocation entries can be
configured to single fcid allocation as per Configuration Guide.
FLOGI-1-MSG_FLOGI_REJECT_TOO_MANY_LOGINS: [VSAN [dec], Interface
Explanation
An FLOGI was rejected because the FL-Port has reached the maximum allowed number
of devices.
Reduce the number of devices on the loop.
Recommended Action
FLOGI-1-MSG_NPIV_NOT_SUPPORTED_WITH_TRUNKING: [VSAN [dec], Interface
The N_Port requested NPIV, but this platform does not support NPIV on trunking
Explanation
F_Ports.
Disable NPIV, or move the N_Port to a switch that supports NPIV on trunking
Recommended Action
F_Ports.
FLOGI-2-MSG_FLOGI_REJECT_NO_ACL_TCAM_AVAILABLE: [VSAN [dec],
Explanation
An FLOGI was rejected because the ACLTCAM hardware resource is completely used.
Reduce the number of nodes.
Recommended Action
FLOGI-4-MSG_VF_FLOGI_FROM_NON_CISCO_OUI: [VSAN [dec], Interface
Explanation
This interface received an FLOGI with VF bit set from a nonCisco OUI; in this release
Virtual Fabrics are not supported on interfaces connected to third-party devices.
Recommended Action
Set the trunk mode of this interface to off.