Port Messages; Pmalloc-6 - Cisco AP775A - Nexus Converged Network Switch 5010 Reference

Nx-os system messages reference
Hide thumbs Also See for AP775A - Nexus Converged Network Switch 5010:
Table of Contents

Advertisement

Chapter 2
System Messages and Recovery Procedures
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
Error Message
Error Message

PORT Messages

This section contains the PORT messages.
PORT-2
Error Message
disabled)
PORT-3
Error Message
OL-15994-03
PMALLOC-6-MMAP_SIZE Format: MMAP size is: %d\n
In PMALLOC lib, Memory map size.
Explanation
Parameters: Memory Map size ...
Recommended Action
No action is required.
PMALLOC-6-SBRK_FAILURE Format: sbrk failed in %s\n
In PMALLOC lib, return vlaue from MORECORE failed.
Explanation
Parameters: Function name ...
Recommended Action
No action is required.
PORT-2-IF_DOWN_ERROR_DISABLED: Interface [chars] is down (Error
The system has detected that the interface has has detected an error during the
Explanation
configuration.
Recommended Action
Collect more information about the failed interface using the command 'show
port internal all interface [char]'. In most cases, you can recover using the following commands
'config terminal', 'interface [char]', 'shutdown', 'no shutdown' on the interface or remove and reinsert
the fiber optic cable.
PORT-3-IF_SFP_ALARM: Interface [chars], [chars]
Explanation
There was an alarm on the transceiver module.
Enter the show interface transceiver details command to obtain more
Recommended Action
information.
Cisco NX-OS System Messages Reference
PORT Messages
2-503

Advertisement

Table of Contents
loading