Error Message
Flow Control state changed to [chars]
Error Message
Error Message
[chars]
Error Message
exceeds the configured threshold [chars]
Error Message
fallen below the configured threshold [chars]

EUREKA_USD Messages

This section contains the EUREKA_USD messages.
EUREKA_USD-3
Error Message
OL-15994-03
ETHPORT-5-IF_TX_FLOW_CONTROL: Interface [chars], operational Transmit
Explanation
Operational transmit flow control has changed when link came up.
No action is required.
Recommended Action
ETHPORT-5-IF_UP: Interface [chars] is up [chars]
The interface is up in the mode specified, if applicable.
Explanation
No action is required.
Recommended Action
ETHPORT-5-SPEED: Interface [chars], operational speed changed to
Operational speed has changed when link came up.
Explanation
No action is required.
Recommended Action
ETHPORT-5-STORM_CONTROL_ABOVE_THRESHOLD: Traffic in port [chars]
Traffic on specified port is beyond the configured storm-control threshold, and the
Explanation
excess traffic is being dropped.
Identify source of traffic storm.
Recommended Action
ETHPORT-5-STORM_CONTROL_BELOW_THRESHOLD: Traffic in port [chars] has
Traffic on specified port has returned to within configured storm-control threshold.
Explanation
No action is required.
Recommended Action