Dell PowerConnect 6024F Command Line Interface Reference Manual page 362

Command line interface (cli) guide (.htm)
Hide thumbs Also See for PowerConnect 6024F:
Table of Contents

Advertisement

The following example configures community access string public to permit SNMP read-write
access for the Out-of-Band port only.
Console (config)# snmp-server community public rw 192.175.1.10
type oob
snmp-server host
The snmp-server host global configuration command specifies the recipient of Simple Network
Management Protocol Version 1 or Version 2 notifications. To remove the specified host, use the no
form of this command.
Syntax
snmp-server host {ip-address | hostname} community-string [traps | informs] [1 | 2] [udp-
port port] [filter filtername] [timeout seconds] [retries retries]
no snmp-server host {ip-address | hostname} [traps | informs]
ip-address—Specifies the IP address of the host (targeted recipient). For information
about specifying an out-of-band IP address, see the user guidelines.
hostname—Specifies the name of the host. (Range:1-158 characters)
community-string—Specifies a password-like community string sent with the notification
operation. (Range: 1-20)
traps—Indicates that SNMP traps are sent to this host.
informs—Indicates that SNMP informs are sent to this host. Not applicable to SNMPv1.
1—Indicates that SNMPv1 traps will be used.
2—Indicates that SNMPv2 traps will be used.
port—Specifies the UDP port of the host to use. (Range:1-65535)
filtername—Specifies a string that defines the filter for this host. If unspecified, nothing
is filtered. (Range: 1-30 characters)
seconds—Specifies the number of seconds to wait for an acknowledgment before
resending informs. (Range: 1-300)
retries—Specifies the maximum number of times to resend an inform request.
(Range: 0-255)
Default Configuration
The default is to send SNMPv2 traps to the host.
The default UDP port of the host to use is 162.
The default timeout period to wait for an acknowedgement before resending informs is 15
seconds.
362
SNMP Commands

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerconnect 6024

Table of Contents