Dell PowerConnect 6024F Command Line Interface Reference Manual page 276

Command line interface (cli) guide (.htm)
Hide thumbs Also See for PowerConnect 6024F:
Table of Contents

Advertisement

The following example displays detailed optical transceiver diagnostics.
Console# show fiber-ports transceiver detailed
Port
----
g1
g2
g3
Temp – Internally measured transceiver temperature.
Voltage - Internally measured supply voltage.
Current – Measured TX bias current.
Output Power – Measured TX output power.
Input Power – Measured RX
Tx Fault – Transmitter fault
LOS – Loss of signal
Data ready – Indicates transceiver has achieved power up and data
is ready.
276
PHY Diagnostics Commands
Temp
Voltage
Current
[C]
[Volt]
[mA]
-----
-------
-------
48
5.15
43
5.15
Copper
Power
Output
Input
[dBm]
[dBm]
------
50
1.7
10
1.7
received power.
TX
LOS
Fault
------ -----
---
1.7
No
No
1.7
No
No
Data
Ready
-----
Yes
Yes

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerconnect 6024

Table of Contents