Reading The Existing Screen Data (Application) File - Omron NT - SUPPORT TOOL FOR WINDOWS V4 Operation Manual

Table of Contents

Advertisement

Operation of Screen Data (Application) File
Clock Address

3-3-2 Reading the Existing Screen Data (Application) File

I/O Comments
Set a comment concerning the area set as the PT Status Control Area, a PT
Status Notify Area, or a Window Control Area.
As a comment, a character string of up to 16 characters can be set.
When the PT is set to the NT21, the addresses must be set to read the clock
from the PLC host. This setting is not necessary for other models of PT.
If the PT is set to the NT21 on the tools page of the PT configuration dialog box,
the clock address dialog box shown below appears. Always set an address
when using the clock function (data displays, screen display history, or alarm
history).
PLC Address
Set the area and the address of the first word from which to read the clock data.
A Clock Data Area will be defined consisting of 4 words starting at the specified
address.
I/O Comments
Set a comment for the address used to define the Clock Data Area. Up to 16
character can be input.
S PLC Address Dialog Box
This dialog box is set in the same way as the one for the PT configuration dialog
box.
To read the screen data that is saved in a file, select [File]
window menu.
Section
3-3
[Open] from the main
53