Omron NT - SUPPORT TOOL FOR WINDOWS V4 Operation Manual page 202

Table of Contents

Advertisement

Data Input
Guidance
(Can only be set for PTs with color display.)
White, black, blue, red, magenta, green, cyan, yellow
Background:
Specify the background color of the numeric value displayed
in the thumbwheel switch.
(Can only be set for PTs with color display.)
White, black, blue, red, magenta, green, cyan, yellow
Settings
Table Entry: Specify the table entry number of the numeral memory table entry
where input data is stored.
Display Type
Decimal:
Specify this item to display the input numeric value in decimal.
Hexadecimal: Specify this item to display the input numeric value in hexade-
cimal.
Format
Integer:
Specify the number of digits of the integer part of the input
data.
Decimal:
Specify the number of digits of the decimal fraction part of the
input data.
Limit
Maximum:
Specify the upper limit of the input data.
Minimum:
Specify the lower limit of the input data.
Display Sign: Specify if a sign is displayed for a negative value.
*1: An input method for a negative value in decimal differs between the following
types of PT.
S With NT20, NT20S, NT30, NT30C, NT600S, NT620S, NT620C, and
NT625C:
Input F to indicate a negative value in the most significant digit.
(e.g., F0000008)
S With NT21, NT31, NT31C, NT631, and NT631C:
Input "–" (negative sign) in the most significant digit.
(e.g., –8)
Interlock
Refer to 6-1-12 Interlock.
Each time a numeral input or thumbwheel object is newly created, a numeral
table entry number (where input data is stored) is automatically set as 0 1 2...
incrementally (table entry number after the last set one will be the next default
number). A numeral table entry number can be changed by displaying the prop-
erty setting dialog box. (It is also possible to change it later.)
Section
6-4
*1
*1
189