Omron NT - SUPPORT TOOL FOR WINDOWS V4 Operation Manual page 550

Table of Contents

Advertisement

Error Messages
D
Due to length limitation, Input Key –
String Touch Switch is only displaying
part of the label message.
F
[Fixed Display Mark] – smoothing not
supported. It is ignored.
I
Image Table entry has been converted.
Incompatible PT hardware connected;
communication aborted.
Input key-window/keyboard screen num-
ber is not within the valid range. Mini-
mum value restored.
L
Library Table Entry has been converted.
M
Memory access mismatched; commu-
nication aborted.
Memory utilization has exceeded the
XXX bytes limit by YYY bytes.
Memory utilization has exceeded the
XXX bytes limit by YYY bytes.
More than one Numeral Input/Thumb-
wheel are referring to Numeral Table
entry 0.
N
Notify Area not specified.
Control Area not specified.
Number of [Object name] has exceeded
the XXX limit by YYY.
[Numeral Input] – Total number of integer
and decimal exceeds limit. It is dis-
carded.
548
Error Message
Corrective Action
With NT620S, NT620C and NT625C, if a
character string input is selected as the
touch switch function, up to 80 characters
can be set for an input character string.
With NT21, NT31, NT31C, NT631 and
NT631C, however, although up to 80 char-
acters can be set for a label, the limit is 40
characters for an input character string (a
character string that is input using a touch
switch).
The mark is automatically displayed with-
out smoothing processing.
If the converted image code differs from
the code of the image data that is to be
displayed, correct the code.
The PT model between the screen data
and the target PT is mismatching on down-
loading/uploading. Check the contents of
PT Configuration.
Create the window/keyboard screen for a
screen number in the range 1900 to 1979
and convert the window/keyboard screen
number set for the touch switch according-
ly.
If the converted library code differs from
the code of the library data that is to be
displayed, correct the code.
Target PLC vendor type or PT type is mis-
matching between the Support Tool and
PT hardware. Confirm the Support Tool
and PT side PLC vendor and PT type is
mismatching.
Delete several elements.
Delete several elements and screens.
Set different numeral memory table entry
numbers at the numeral input and thumb-
wheel switch properties.
Set the PC (PLC) address for the PT sta-
tus control area/PT status notify area after
selecting [Tools] – [PT Configuration].
Delete several elements.
Create the numeral input field again. Cor-
rect the screen data and the program in
the host so that numeric values such as
maximum/minimum check values and an
input value of up to 8 digits will suffice.