Omron NT - SUPPORT TOOL FOR WINDOWS V4 Operation Manual page 478

Table of Contents

Advertisement

Data Conversion
Correction related to the system initializing screen (Host Connect screen)
Correction related to extended screens
Conventional models:
S Conversion result, error message and corrective action
Status before
Conversion
With a conventional
With a new model,
model, a range that
the range is cor-
does not fit the
rected so that it
touch switch size is
agrees with the
specified as the dis-
touch switch posi-
play range.
tions.
When the system initializing screen is converted, conversion is executed as
shown below due to differences in screen numbers and elements that can be
registered between conventional and new models.
S Difference
New models:
Conventional models:
S Conversion result, error message and corrective action
Status before
Conversion
With a conventional
With a new model,
model, elements
the screen No. is
that cannot be reg-
modified to 9000.
istered on a new
Elements that can-
model are regis-
not be registered for
tered.
a new model are re-
moved.
When an extended screen is converted, an error message may be displayed due
to differences in the handling of an extended screen between conventional and
new models.
S Difference
New models:
Conventional models:
S Conversion result, error message and corrective action
Status before
Conversion
With a conventional
With a new model,
model, the screen
the screen is
number of an ex-
treated as a stan-
tended screen is
dard screen.
used for a standard
screen.
A window/keyboard screen can be specified at any
desired position.
Status after
Error Message
Conversion
Some screen ele-
ments exceed
frame size. The ele-
ments will not be
downloaded to PT
Hardware.
Screen No. 9000
Only fixed display elements (excluding image data
and library data) can be registered.
Screen No. 1999
All kinds of element can be registered.
Some elements that need communications with a
host may not be displayed correctly.
Status after
Error Message
Conversion
This screen does
not support XXX. It
is discarded.
Extended screens are not supported.
Extended screens can be used as standard screens.
Status after
Error Message
Conversion
The screen no. XXX
was an Extended
Screen that is not
supported by this
model, so it is con-
verted to a standard
screen.
Appendix A
Corrective Action
If the position and the
range of the window to
be displayed is inconve-
nient for operation, cor-
rect the position and the
range. (Refer to 5-4
Window/Keyboard
Screens.)
Corrective Action
Correct the screen so
that the same screen as
before the conversion is
created using fixed dis-
play elements excluding
image/library data. (Re-
fer to 5-8. Host Connect
Screen (System Initializ-
ing Screen))
Corrective Action
––
469