Data Conversion
Correction related to a touch switch for which a pop-up window/keyboard function is set
Correction related to the touch switch for which the copy function is set
476
S Conversion result, error message and corrective action
Status before
Status after
Conversion
Conversion
––
Touch switch posi-
tion and size may
change.
If a touch switch assigned the pop-up window/keyboard function is converted be-
tween a conventional and a new model, conversion is executed in the manner
shown below due to differences in the range of screen numbers of the touch
switch window/keyboard screen.
S Difference
New models:
Conventional models:
S Conversion result, error message and corrective action
Status before
Conversion
With a new model,
With a conventional
the touch switch for
model, the window/
which a pop-up win-
keyboard screen
dow/keyboard func-
number is corrected
tion is set is regis-
to 1900.
tered to the symbol
manager.
If a touch switch assigned the copy function is converted between a conventional
and a new model, conversion is executed in the manner shown below due to dif-
ferences in the range of numeric values that can be input.
S Difference
New models:
Conventional models:
S Conversion result, error message and corrective action
Status before
Conversion
With a new model,
With a conventional
a touch switch for
model, a value
which the copy set-
greater than
ting function is set
100000000 is cor-
with a numeric val-
rected to 99999999
ue greater than
or a value smaller
100000000 or
than –10000000 is
smaller than
corrected to
–10000000 speci-
F0000000.
fied is registered to
the symbol manag-
er.
Error Message
––
Screen numbers of window/keyboard screen:
1 to 3999
Screen numbers of window/keyboard screen:
1900 to 1979
Status after
Error Message
Conversion
Input Key-Window/
Keyboard screen
number is not within
the valid range.
Minimum value re-
stored.
As a constant for the copy setting function, a numeric
value of up to 10 digits can be input.
As a constant for the copy setting function, a numeric
value of up to 8 digits can be input.
Status after
Error Message
Conversion
[W]
Constant Value is
out of limit. Maxi-
mum value re-
stored.
Appendix A
Corrective Action
Correct the touch switch
position and size as
needed. (Refer to 6-8
Touch Switches)
Corrective Action
Create the window/key-
board screen for a
screen number in the
range 1900 to 1979 and
correct the window/key-
board screen number
set for the touch switch
accordingly. (Refer to
5-4 Window/Keyboard
Screens and 6-8-4 Pop-
up Window/Keyboard
Function Touch Switch.)
Corrective Action
Correct the screen data
or the program in the
host so that a constant
of up to 8 digits suffices.
(Refer to 6-8-6 Copy
Setting Touch Switch.)