Data Conversion
Correction related to the label component of standard lamp and touch switch
Correction related to 'switch screen' screen numbers
482
S Difference
New models:
Conventional models:
S Conversion result, error message and corrective action
Status before
Conversion
With a new model,
With a conventional
a graph for which a
model, if a % value
value greater than
is outside the allow-
100000000 or
able range, it is re-
smaller than
placed as shown
–10000000 is set
below: for a 100%
for a % value is reg-
value, the existing
istered.
value is corrected to
100, for a 0% value,
it is corrected to 0,
and for a –100%
value, it is corrected
to –100.
In the conversion of the data between a NT31/631-V2 or later model and a
NT31/631-V1 or earlier model, conversion is executed in the manner shown be-
low due to differences in the label data of standard lamp and touch switch.
S Difference
V2 or later models:
Other models:
S Conversion result, error message and corrective action
Status before
Conversion
With a V2 or later
With a V2 or earlier
model, a standard
model, standard
lamp/touch switch
lamp/touch switch
label type is set to
label type is set to
Static' and On/Off
Static' and On label
label descriptions
description will be
are different.
set to that of Off la-
bel.
With a V2 or later
With a V2 or earlier
model, set Standard
model, standard
Lamp/Touch Switch
lamp/touch switch
label to "Label<\n>
label set to "Label"
in <\n> multiple
(Default).
<\n> lines".
From a 31/631-V2
Label properties are
model application
set to default.
copy Touch Switch/
Standard Lamp with
Label Type set to
Numeral Display or
String Display and
paste in an applica-
tion for a model ear-
lier than V2.
In the conversion of the data between a V2 or later model and a V1 or earlier mod-
el, conversion is executed in the manner shown below due to differences in the
new device monitor screens available in V2 or later models.
A numeric value of up to 10 digits can be input for a %
value.
A numeric value of up to 8 digits can be input for a %
value.
Status after
Error Message
Conversion
[W]
[Object Name] – %
value is out of limit.
Default values re-
stored for 100%,
0% and –100%.
On label and Off label can be different.
On label and Off label should be same.
Status after
Error Message
Conversion
[W]
Label Type-On Off
Static is not sup-
ported. Label will
set to Off descrip-
tion.
[W]
Label Type-Static
not supported. La-
bel will set to de-
fault.
[W] Label Type-Nu-
meral Display not
supported. Label
will set to default.
(Or)
[W] Label Type-
String Display not
supported. Label
will set to default.
Appendix A
Corrective Action
Correct the screen data
or the program at the
host so that a constant
of up to 8 digits suffices.
(Refer to 6-9 Graph.)
Corrective Action
None
None
None