Creating the Sample Data
390
(6) Adjust the size and position of [Start] button frame.
(7) Adjust the position of the label "Auto" by dragging it.
S Creating the [Man.] button
(8) Copy the [Auto] button and paste it onto the data creation screen.
(9) Move the [Auto] button pasted at the upper left area of the screen to the
[Man.] button position.
(10) Double click the moved button and modify the properties as shown below.
Note that other properties must be left unchanged.
Settings
Copy From
Label
Label
*1: Press
S Creating the [Step] button and the [Reset] button
(11) Create the [Step] button and the [Reset] button in the same manner as the
[Man.] button.
For the [Step] button and the [Reset] button, change the properties as
shown below.
Settings
Copy From Numeral Table
General
Label
S Creating the button group title bar
(12) Select [Objects] (menu bar)
(13) While pressing the shift key, drag the polyline from start point to the se-
cond vertex, and then from the second vertex to the third vertex. Repeat
this procedure to create the desired form. Release the Shift key just before
reaching at the last point.
Numeral Table
String Table
Code
Entry (Text Box)
to set the label.
[Step] but-
ton
n
String Table
Code
Entry (Text Box)
12
n, Step
[Fixed Display]
Section
9-3
n
11
n, Man.
*1
[Reset]
button
n
13
n, Reset
[Polyline].