Omron NT - SUPPORT TOOL FOR WINDOWS V4 Operation Manual page 486

Table of Contents

Advertisement

Data Conversion
Corrections related to lamp/touch switch label
Conversion from conventional models to V2/V3 models
Conversion from V2/V3 models to conventional models
Status of label before conversion
Static
One line
Two or more lines
On Off Static
Off label – one line Label Type – On Off Static not supported. Label will be set to Off Description.
Off label – two or
more lines
Numeral Display
String Display
In the conversion of data between a V2 model and a non-V2 model/conventional
model, conversion is executed in the manner shown below due to differences in
the new functions of the lamp/touch switch label added to V2 models.
S Difference
V2/V3 models: Multiple lines of label, On Off Static label, Numeral/String Dis-
play label can be set.
Conventional models, non-V2/V3 models: Only fixed display label (one line)
can be set.
S Conversion result, error message and corrective action
Status before
Conversion
With a conventional
With a V2/V3 mod-
model, a fixed dis-
el, multiple label
play object is used
lines can be set (no
with a label to dis-
need to add a fixed
play multiple label
display object.)
lines.
With a conventional
With V2/V3 models.
model. A numeral/
numeral/string dis-
string display object
play labels can be
is created on a
set.
lamp/touch switch.
*1: It is also possible to use the screen data after conversion without perform-
ing the above modification.
S Conversion result, error message and corrective action
Status before
Conversion
With a V2/V3 mod-
According to the
el, a lamp/touch
status before con-
switch allocated a
version, the label
newly added func-
will be converted to
tion is registered in
a default status (La-
the symbol manag-
bel) or OFF label
er.
(see below).
S Label error messages following conversion from V2 models to conventional
model.
Error Message
Label Type – Static not supported. Label will be set to Off Description.
Label Type – Static not supported. Label will be set to default.
Label Type – On Off Static not supported. Label will be set to Default.
Label Type – Numeral Display not supported. Label will be set to Default.
Label Type – String Display not supported. Label will be set to Default.
Status after
Error Message
Conversion
*1
*1
Status after
Error Message
Conversion
See below
Appendix A
Corrective Action
Create multiple label
lines using Label proper-
ty (6-5-1 Standard
Lamps or 6-8 Touch
Switches) and delete
fixed display objects.
Select "Numeral Dis-
play" or "String Display"
as the Label Type in La-
bel Property for the
lamp/touch switch. Make
the setting as required.
Delete the numeral/
string display objects
created on the lamp/
touch switch.
Corrective Action
Create a fixed display
object or a numeral/
string display object on
a lamp/touch switch
(use Group function if
needed) so that it
matches the status be-
fore conversion.
477

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nt-series support tool for windows 4

Table of Contents