Graphs
246
(3) Select [Edit] (menu bar) – [Select Object]. (Place where graph or % display
does not exist.)
The components of a trend graph (trend graph, percentage values) are dis-
played in a list. The line numbers that correspond to the individual percent-
age values are displayed.
If you click a line in the list, the corresponding percentage value display is
selected in the screen to make the correspondence between the line and the
percentage value clear.
Instead of the operation in step (3) above, right-clicking the mouse on the trend
graph
[Edit Object]
% display where % display and frame does not exist
centage values displayed near the click point are displayed in a list.
S When displaying a trend graph, the display points are determined by calculat-
ing the percentage value based on the values for 100%, 0%, and –100%.
If the 100% value, 0% value, and –100% value are set as indicated below, refer-
ence values are displayed in the trend graph as shown below.
Value referred to: 3000
Value referred to: 1500
Value referred to: 0
Value referred to: –1000
Value referred to: –2000
right-clicking the mouse on the trend graph near by the
100%
50%
0%
–50%
–100%
Section
6-9
[Select Object], the per-