Copying An Entire Table - Omron NT - SUPPORT TOOL FOR WINDOWS V4 Operation Manual

Table of Contents

Advertisement

Operating the Application Manager
Operation using the mouse (1)
Operation using the mouse (2)
Operation using the menu

4-2-9 Copying an Entire Table

Caution:
Reference: S To start up second Support Tool, select [Import Component] from [File] menu,
Operation using the mouse (1)
Operation using the mouse (2)
68
For details, refer to Section 7 Memory Table Setting or Section 8 Editing Graphic
Data.
Double click the icon of the table data to be edited.
Make a right click on the icon of the table data to be edited, then select [Modify].
(1) Select [Tools] in the menu bar, then choose [Table], [Image Editor], [Library
Editor] or [Mark Editor].
(2) If [Table] is chosen, select the tab of the table to be edited.
An entire table can be copied between the screen data files of the same PT mod-
el by starting up two Support Tools.
Copying of tables, screens, and objects between two screen data files involves
addition or overwriting of PLC address. Please check the movement sufficiently
before shifting to actual operation.
For details, refer to 3-3-6 Importing Components from Different Screen Data
File (Starting Up the Second Support Tool).
S If the whole table is copied, all the contents in the specified table are copied
collectively. For method to copy the individual data in a table, refer to Section 7
Memory Table Setting or Section 8 Editing Graphic Data.
S A check box for "Overwrite PLC Address" appears when copying the whole
table indicated below. If this check box is checked, PLC address setting is over-
written. If not checked, settings such as initial value will be overwritten but the
PLC address setting remains the same. Note that I/O comments are not copied
even if the PLC address is overwritten. If you need the same I/O comment,
copy the I/O comment.
Bit memory table, Extended I/O output table, Numeral table, String table, F-
Key input notify table
(1) Specify the table data icon.
Multiple tables can be selected by dragging the mouse cursor while pressing
the Shift key or Ctrl key.
(2) Click right button of the mouse on the selected table data icon, then select
[Copy].
(3) Click right button of the mouse on the desired table in the table data icon dis-
play area of another Support Tool, then select [Paste].
(4) In the confirmation dialog box, click the
"Overwrite PLC Address" appeared in the dialog box, make the setting as
required.
(1) Specify the table data icon.
Multiple tables can be selected by dragging the mouse cursor while pressing
the Shift key or Ctrl key.
Section