Monitoring the Unit

Front Panel LEDs

G.703-Compatible Unit

Upon power up, the first three LEDs blink in sequence, indicating a successful
start configuration. The green PWR LED lights whenever power is applied to the
board. Loop LEDs blink until the loop has been synchronized and then remain off.
6-6
E1 HDSL
TERMINAL
NETWORK
LED
Meaning
Local
The local E1 interface has a loss of signal.
Remote
The remote E1 interface has a loss of signal.
Loop Bk
A bilateral loopback has been initiated for testing the equipment
connected to this unit.
PWR
Power is applied to the unit.
FAIL
The processor has halted and repairs are required.
Loop A
A failure in HDSL Loop A. (The LED will blink at board power up until the
loop has been synchronized.)
Loop B
A failure in HDSL Loop B or the loop has been disabled. (The LED will
blink at board power up until the loop has been synchronized.)