Environmental Specifications - Xerox DocuPrint 100 Installation Planning Manual

Xerox docuprint 100: install guide
Hide thumbs Also See for DocuPrint 100:
Table of Contents

Advertisement

Service outlet
configuration
5 Wire 380 V
5 Wire 380 V
5 Wire 380 V
5 Wire 400 V
5 Wire 400 V
5 Wire 400 V
5 Wire 400 V
5 Wire 400 V
5 Wire 400 V
Printer power
outlet/cord voltage
configurations—
50 Hz

Environmental specifications

Installation Planning Guide
Table 6-5. Printer (50 Hz) WYE (Star) 380 and 400 voltage (Continued)
Measurement
Line 1 to neutral
Line 2 to neutral
Line 3 to neutral
Line 1 to line 2
Line 2 to line 3
Line 1 to line 3
Line 1 to neutral
Line 2 to neutral
Line 3 to neutral
For 50 Hz systems outlet/power cord configurations, consult your
local service representative to determine the type of plug and
receptacle to use.
When you select a site location for your DocuPrint printer, avoid
environments with extreme variations in temperature and other
hazards, such as excessive dust or humidity. Recommended
environmental ranges for the work area are as follows:
Table 6-6. Environmental specifications for 96/4635/180 printers
Condition
Operating
temperature:
Humidity:
Altitude:
Nominal
220 V RMS
220 V RMS
220 V RMS
400 V RMS
400 V RMS
400 V RMS
230 V RMS
230 V RMS
230 V RMS
Range
Recommended:
68° F to 76° F /
20° C to 24° C
Minimum:
50° F / 10° C
Maximum:
85° F / 29° C
Recommended:
45% ±10%
Minimum:
30%
Maximum:
65%
Normal:
Up to 6,000 feet / 1,830 m
above sea level
Maximum:
9,000 feet / 2,743 m above
sea level.
Range
198-242 V RMS
198-242 V RMS
198-242 V RMS
358-438 V RMS
358-438 V RMS
358-438 V RMS
207-253 V RMS
207-253 V RMS
207-253 V RMS
6-5