Installation

Panel Mounting

2-2
SV100A/SV10AC User Guide
marked, in close proximity to the recorder, and easily accessible to the
operator. ▲
Warning The recorder should be considered as permanently connected.
Disconnection from the supply must be possible via a customer-supplied
switch or circuit breaker. This disconnection device should be clearly
marked, in close proximity to the recorder, and easily accessible to the
operator. ▲
The instrument is sized to fit in a 5.43 x 5.43 inches (138 x 138 mm) panel
cutout and requires 9.25 inches (235 mm) behind panel depth. Actual
dimensions of the instrument are shown in Figures 2–1 through 2–3. The
recorder can be mounted at most any angle. Ensure that you have the
proper clearances.
1. Cut a panel opening that is 5.43 x 5.43 inches (138 x 138 mm) in the
installation location. If you are installing multiple recorders side by side,
refer to Figure 2–3. The section labeled "PANEL CUTOUT...FOR
MULTIPLE MOUNTING..." depicts the minimum spacing requirements
between recorders.
2. If not already done, remove any packaging material from the recorder.
Always handle the unit carefully to avoid damaging the display or
scratching the touch screen surface.
3. If necessary, remove the four rubber feet from the bottom of the recorder.
4. Insert the recorder into the panel opening from the front.
5. For Seismic Only (continue to step 6 for non-seismic installation): Slide
the retainer plate over the end of the recorder. Slide the plate up to the
panel (refer to Figure 2–4).
6. Hold the recorder firmly in place against the panel, and install one of the
jackscrews by inserting the jackscrew nut into the keyhole located on the
side of the recorder case. For seismic installation, ensure that the jackscrew
traps the retainer plate against the panel.
7. Using a screwdriver, screw the jackscrew leadscrew in until the jackscrew
holds the panel against the front of the recorder bezel. Do not completely
tighten the leadscrew at this time.