Thermo Scientific SpeedVac SPD210 Installation And Operation Manual

Thermo Scientific SpeedVac SPD210 Installation And Operation Manual

Vacuum concentrator

Advertisement

Quick Links

SpeedVac™ SPD210
Vacuum Concentrator
Installation and Operation
80302131 • Revision A • September 2018

Advertisement

Table of Contents
loading

Summary of Contents for Thermo Scientific SpeedVac SPD210

  • Page 1 SpeedVac™ SPD210 Vacuum Concentrator Installation and Operation 80302131 • Revision A • September 2018...
  • Page 2 IMPORTANT: Read this instruction manual. Failure to follow the instructions in this manual can result in damage to the product, injury to operating personnel, and poor equipment performance. CAUTION: All internal adjustments and maintenance must be performed by qualified service personnel. DISCLAIMER: Thermo Fisher Scientific Inc.
  • Page 3: Table Of Contents

    Contents Introduction ..............1 Safety Precautions ............2 Operating Standards............ 3 Product Specifications ..........3 Environmental Conditions......... 3 Installation..............4 Contents ..............4 Installation of SPD210 ..........4 Operation..............5 Description Of Control Panel ........5 Manual Run.............. 7 Auto Run..............7 Drying Rate ..............
  • Page 4: Introduction

    Introduction Thermo Scientific Savant SpeedVac™ SPD210 vacuum concentrator offers fast, reliable processing of samples. It effectively removes non-aggressive organics such as methanol, acetonitrile, water and HPLC fractions. The combination of vacuum applied to the sample chamber from an external source and centrifugal action promotes solvent evaporation without sample loss due to foaming or bumping.
  • Page 5: Safety Precautions

    Safety Precautions In this manual, the following symbols and conventions are Below are important safety precautions that apply to this used: product: This symbol when used alone indicates WARNING: Disconnect the unit from all power important operating instructions which reduce sources before cleaning, troubleshooting, or the risk of injury or poor performance of the unit.
  • Page 6: Operating Standards

    Operating Standards Product Specifications Operative Power* 115 VAC; 60 Hz; 8 amps 230 VAC; 50 Hz; 6 amps ® Vacuum Chamber TEFLON coated chemical resistant aluminum casting Cover Glass cover - includes a safety interlock Induction Motor Maintenance free Bearings Standard Chamber temperature 35°C to 65°C, 5°C increments...
  • Page 7: Installation

    Inspection. Inspect the unit and accessories for damage that may have occurred during shipment. Should there be any damage, report it to the carrier and contact Thermo Scientific immediately. Make sure the carrier inspects the damage and leaves an inspection report. Register any claims for shipping damage against the carrier or his agent.
  • Page 8: Operation

    Operation Connect the power cord to the power inlet on the right side of Rotor installation. Open the lid of the rotor chamber. the unit and plug it into the appropriate outlet. Turn on the Visually align the pin on the drive shaft with the groove on the main power switch located on the front of the unit in the lower bottom of the rotor.
  • Page 9 manner. The selected parameters is shown by the Table 2. Program Settings corresponding indicator that is illuminated. Default UI 7. Minus (“-”) - Decrements the value of the selected Program Description parameters parameter. 8. Plus (“+”) - Increments the value of the selected Temperature: 45°C parameter.
  • Page 10: Manual Run

    spinning. The “Run Time” display counts up. The Table 3. Audible Notifications temperature rises to the set temperature. The “Heat Time” will count down if set point is not set to “CCC” and 1 long beep that lasts for 1 if the temperature set point is not “no”.
  • Page 11: Drying Rate

    c. After the rotor stops spinning, the cover unlocks and • The remaining heat time for the run (“CCC” indicates the lid locked indicator is turned off. The display continuous heating) reverts to last set parameters. • The remaining or elapsed run time, depending on the run type (manual or automatic) d.
  • Page 12: Lid Stay Mechanism

    In the event that your choice of solvents and applications are display and an error tone. Otherwise, during a run the user unique and not listed above, please contact Thermo Scientific cannot open the cover due to vacuum in the concentration Customer Support for advice.
  • Page 13: Rotors And Rotor Blocks

    2. Ensure all glass condensation flask in emptied, cleaned WARNING: Do not use this device in radioactive, and checked for crack before every run. highly reactive or explosive atmosphere. 3. Clean the cover, cover seal and chamber with a soft lint Do not use this device to process any explosive, free cloth with one of the following: radioactive, highly reactive or explosive...
  • Page 14: Accessories

    Rotor Block: For Use With Four-Position Rotor (FPR-4A) All blocks come as a set of two. No. of Tubes/ Working Rotor Block Type Description Vials/ Volumes (ml) Part No Flasks 50 ml conical (30x115 mm) RBA6-30-115 Centrifuge Tubes 15 ml conical (17x120 mm) RBA24-16-100 28x60 mm, 20 ml scintillation vial RBA12-28-58...
  • Page 15: Additional Spd210 System Setup

    Appendix 1 Additional SPD210 System Setup Vacuum Tubing ANT100 Exhaust Bleeder Valve To Pump recovery Post Trap SpeedVac Concentrator SPD210 UVS450 Universal Vacuum Source Figure 5. Semi-Integrated System Bleeder Valve Flexible Vacuum Tubing DVG50 VLP120 Vacuum Pump SpeedVac Concentrator SPD210 RVT450 Cold Trap SCT120...
  • Page 16 Change the oil in the vacuum pump when it becomes brown in color or smells of solvents being evaporated. • Attach a Thermo Scientific VPOF110 Vacuum Pump Oil Filter/Recirculator to your vacuum pump when evaporating acids (e.g., HCl, acetic, TFA) in the SpeedVac™.
  • Page 17: Warranty

    ITEM NO. PART NUMBER DESCRIPTION Default/QTY. 80301723 LID FRAME ASSY 80301570 ASSEMBLY, CHAMBER/HEATER SPD210-115 111-1004-00 SC110A-115 AUTO VALVE ASY 090-1003-00 SPINDLE/MAGNET ASSEMBLY 80301700 FRONT PANEL SILK SCREEN 80301722 BASE WELDED SILK SCREEN 80301735 BACK PLATE ASSY SILK SCREEN M50-0007-01 NEOPREME BUMPER 090-6006-00 SEAL, COVER 80301334...
  • Page 18 ITEM NO. PART NUMBER DESCRIPTION QTY. 121-6000-00 CHAMBER LARGE FINISHED 095-6001-00 PLATE,HEATER MOUNTING 18GA 2024-T3 095-6005-00 Closure plate M60-0015-01 TUBULAR HEATER 120V 80301582 MOTOR&DRIVE MAGNET ASSY 115V 80302067 TORX PAN HEAD SCREW #8-32x5/16 80302061 TORX PAN HEAD #6-32 X 1/4in TITLE TITLE ASSEMBLY, CHAMBER/HEATER...
  • Page 19 ITEM NO. PART NUMBER DESCRIPTION Default/QTY. 80301723 LID FRAME ASSY 80301571 ASSEMBLY, CHAMBER/HEATER SPD210-230 111-1009-00 SC110A-230 AUTOVALVE ASSY 090-1003-00 SPINDLE/MAGNET ASSEMBLY 80301700 FRONT PANEL SILK SCREEN 80301722 BASE WELDED SILK SCREEN 80301735 BACK PLATE ASSY SILK SCREEN M50-0007-01 NEOPREME BUMPER 090-6006-00 SEAL, COVER 80301334...
  • Page 20 ITEM NO. PART NUMBER DESCRIPTION QTY. 121-6000-00 CHAMBER LARGE FINISHED 095-6001-00 PLATE,HEATER MOUNTING 18GA 2024-T3 095-6005-00 Closure plate M60-0015-02 TUBULAR HEATER 240V 80301505 MOTOR&DRIVE MAGNET ASSY 80302067 TORX PAN HEAD SCREW #8-32x5/16 80302061 TORX PAN HEAD #6-32 X 1/4in TITLE TITLE ASSEMBLY, CHAMBER/HEATER SPD210-230...
  • Page 21 ITEM NO. PART NUMBER DESCRIPTION QTY. 80301724 PRODUCT BADGING WINDOW ASSY 15.0 80301729 LID LOWER FRAME ASSEMBLY SPD210 80301332 STRIKER ASSY 80301449 DAMPER 3M- SJ57B1 (12,7x1,3 mm) 80301482 Glass cover 80302033 NUT BRACKET ASSY 80302022 HINGE SOUTHCO-N6-4E-422-20 15.0 80302072 Torx #8-32 x 1/2 Flathead screw M90-0050-01 ADHESIVE,FOAM STRIP 1/16 X 1/ 8 x 3 inch...
  • Page 22 Warranty All Thermo Fisher Scientific products mentioned in this manual (excluding glassware) are warranted against defects in workmanship for one year after the date of delivery to the original purchaser. This warranty is limited to defective materials and workmanship and does not cover incidental or consequential damages.
  • Page 23 IF YOU NEED ASSISTANCE: Thermo Fisher Scientific products are backed by a global technical support team ready to support your applications. Visit www.thermofisher.com/ or call: Countries Sales Services North America +1 866 984 3766 (800) 438-4851 India 1800 22 8374, +91 22 6716 2200 +91 22 6716 2200 China +800 810 5118, +400 650 5118...

Table of Contents