6.3 TROUBLESHOOTING

6.3.1 THE CONSOLE DOES NOT TURN ON

Possible cause
The power supply
The console
(5.5v) does not ar-
does NOT
rive.
turn on.
Display faulty.
At the end of the troubleshooting procedure, test the machine.
Page 42
Components
in-
volved
Generator.
Voltage converter.
Display.
If the display must
be replaced, set the
Wi-Fi using the An-
droid APP.
Cables.
Table 15
New Group Cycle (D92):
Technical Service Guide - Rev. 5.1
What to do:
Disconnect the cable that connects the
transformer to the generator from the
transformer. Pedal and check the volt-
age (note 1).
(pin 1 - 2 / pin 1 - 3 / pin 2-3 Vac)
Check the 2 Led RPM (blinking yel-
low) and the POWER SUPPLY Led
(fixed green).
Check the input voltage to the console
+5.5Vdc.
Turn on the console from the PC (it is
OK if the display turns on).
Note: it is also possible to check the sta-
tus of the cable connecting the display
to the transformer; if it is OK, the green
LED on the transformer turns on.
It can be checked if the console is not
functioning by connecting a "power
bank" normally used to recharge cell
phones or a PC with USB - Mini USB
cables.
If the display does not turn on even in
this manner, replace the display.
Check the continuity of the positive
and negative pole.
Document uncontrolled when printed