Therefore, the procedure is as follows:
1- disconnect the USB cable; wait approx. 10 second; reconnect the USB cable (identified with the
red ring) to the PC;
2- install the calibration database if necessary.
Click Finish, to the bottom right, to return to the initial screen.
ATTENTION: after loading the Watt Sensor board sw, the Watt Sensor board must be repro-
grammed (for details see "10.3 watt sensor board programming").
10.2.2
WATT SENSOR ID (NEW ELECTRONICS REV. 2)
The message appears: "Disconnect and reconnect the USB plug (of the GC cable) previously
connected to the pc, then click next button".
The procedure to follow is described below:
1- disconnect the USB cable; wait approx. 10 second; reconnect the USB cable (identified with the
red ring) to the PC;
2-Click Next, to the lower right, to continue;
At this point, a window appears that displays the sw update progress. Wait for the update to finish.
Page 122
Technical Service Guide - Rev. 5.1
Figure 95
Document uncontrolled when printed
New Group Cycle (D92):