Technogym Group Cycle D92 Technical Service Manual page 65

Table of Contents

Advertisement

New Group Cycle (D92):
Technical Service Guide - Rev. 5.1
Figure 40
(1/8)
45°
(1/8)
Figure 41
Document uncontrolled when printed
(1/8)
90°
(1/8)
(1/8)
(1/8)
1.
Remove the console, without disconnect-
ing it, to access the USB socket and power
it (PC, battery charger, power bank).
2.
Press PLAY + LEFT ARROW + RIGHT
ARROW together for 4 seconds. The cali-
bration screen will appear.
3.
Press PLAY to store point 0.
4.
The display will blink for two seconds,
then the lower number will increase by
one unit.
5.
Turn the knob 1/8 of a full rotation and
press PLAY.
6.
Turn the knob 1/8 of a full rotation and
press PLAY, repeat the operation until the
END screen appears.
There are 36 levels to be stored, and 20 are
(1/8)
shown during equipment operation. There-
fore, the calibration is more accurate than
what the customer views while using the
device.
Page 65